• New Hospivac 350 suction

    New Hospivac 350 .. Made In Italy MAIN APPLICATIONS: Emergency Dept. Operating Theatre General Surgery Neurosurgery Liposuction Obstetrics Dental Practice
    Read More slide_1
  • Bed KS 858


    Read More slide_2
  • surton 120D Diathermy

    •SURTRON 120® is a high frequency electrosurgical equipment which is suitable to light and medium surgery.
    Read More slide_3
  • CMS6000 Patient Monitor

    CMS6000 features in high cost-performance, high safety and low power consumption. To ensure monitoring quality and reduce operation risk, it adopts full-isolation(floating).
    Read More slide_4
  • Operating Lamp 700/500


    Read More slide_5

N8-shape

Rate this item
(0 votes)

Applications

1) Skin tightening;
2) Cellulite removal;
3) Face & eyelid lifting;
4) Wrinkle removal.

Energy level: 09, radio frequency: 08s (adjustable).It promotes blood cycle by

Drawing skin; Speed of roller wheelmechanical energyis 40120 turn/minute. The roller wheel Whose rev is adjustable could do mechanical extrusion. Especially the screw
Structure could do massage on skin;

Bipolar radio frequency (electrical energy: 09 energy level (adjustable). It could do body shaping. The two roller wheels are two electrodes caused radio Frequency; Infrared physical therapylight energy: 020W (adjustable). Infrared spectrum
With 940nm could pass through skin, expand blood vessel, stimulate blood Cycle, speed up lymphokinesis, improve diet structure of sufferer Red light designationIf you see red light directly, your eyes would be hurt. So you shall not see the inside of hand piece directly when there is red light.

2. Advantages
It combines many technologies of body shaping and it is number one body Shaping equipment for choosing;
Continual output radio frequency: 1MHz-10MHz (adjustable). It penetrates Through skin to 10mm. It gets energy of radio frequency from epidermal skin to Subcutaneous tissue Hand piece of N8-I has suction of negative voltage with 15kg. It could
Completely suck skin of any body parts to bipolar radio frequency and host System could control output radio frequency according to suction result Fixed point or movement treatment mode of RFpulse and continual treatment
Modecould act on skin which is sucked into hand piece by pulse energy or Continual energy Hand piece of N8-I eradiates infrared spectrum with 940nm could pass through Skin, expand blood vessel, stimulate blood cycle, speed up lymphokinesis, mprove diet structure of sufferer Circumrotate roller wheel of V8-I has evident function of could do mechanical Extrusion. Especially the screw structure could do massage on skin; Radio frequency energy, infrared energy, suction pressure, suction time and Rev of roller wheel are adjustable. So many kinds of specifications above Could help to make many kinds of most available fat sensitive energy act on Available skin area.

3. Specifications
Adsorption press: 0~9 level correspondingabsolute press0-68hg
Adsorption cycle: 1S, 2S, 3S, 4S, 5S, 6S, 7S, 8S. Time interval: 0.5S
Rew of roller wheel: 0rpm, 40 rpm, 50 rpm, 60 rpm, 70 rpm, 80 rpm, 90 rpm, 100
Rpm, 110 rpm, 120 rpm
RF (Radio Frequency): 1~10MHz
RF energy: 0~9 level corresponding to 0~50J/cm3
RF time: 0~7.5s
RF interval: 0.5s
Wave length of infrared ray: 940nm
Power: 0W, 4W, 6W, 8W, 10W, 12W, 14W, 16W, 18W, 20W.
Head of hand piece 40mmx60mm, 30mmx50mm
SwitchCentral key
Power supply mode: AC220V± 10%50Hz/AC110V± 10%60Hz (according to signs on the
Equipment)
Volume625mm× 525mm× 1070mm
Weight 47kg handpiece is included

N8-shape Body slimming machine

1. Applications

1) Skin tightening;
2) Cellulite removal;
3) Face & eyelid lifting;
4) Wrinkle removal.

Energy level: 09, radio frequency: 08s (adjustable). It promotes blood cycle by Drawing skin; Speed of roller wheelmechanical energyis 40120 turn/minute. The roller wheel Whose rev is adjustable could do mechanical extrusion. Especially the screw
Structure could do massage on skin;

Bipolar radio frequency (electrical energy: 09 energy level (adjustable). It could do body shaping. The two roller wheels are two electrodes caused radio Frequency; Infrared physical therapylight energy: 020W (adjustable). Infrared spectrum
With 940nm could pass through skin, expand blood vessel, stimulate blood Cycle, speed up lymphokinesis, improve diet structure of sufferer Red light designationIf you see red light directly, your eyes would be hurt. So you shall not see the inside of hand piece directly when there is red light.

2. Advantages
It combines many technologies of body shaping and it is number one body Shaping equipment for choosing;
Continual output radio frequency: 1MHz-10MHz (adjustable). It penetrates Through skin to 10mm. It gets energy of radio frequency from epidermal skin to Subcutaneous tissue Hand piece of N8-I has suction of negative voltage with 15kg. It could
Completely suck skin of any body parts to bipolar radio frequency and host System could control output radio frequency according to suction result Fixed point or movement treatment mode of RFpulse and continual treatment
Modecould act on skin which is sucked into hand piece by pulse energy or Continual energy Hand piece of N8-I eradiates infrared spectrum with 940nm could pass through Skin, expand blood vessel, stimulate blood cycle, speed up lymphokinesis, mprove diet structure of sufferer Circumrotate roller wheel of V8-I has evident function of could do mechanical Extrusion. Especially the screw structure could do massage on skin; Radio frequency energy, infrared energy, suction pressure, suction time and Rev of roller wheel are adjustable. So many kinds of specifications above Could help to make many kinds of most available fat sensitive energy act on Available skin area.

3. Specifications
Adsorption press: 0~9 level correspondingabsolute press0-68hg
Adsorption cycle: 1S, 2S, 3S, 4S, 5S, 6S, 7S, 8S. Time interval: 0.5S
Rew of roller wheel: 0rpm, 40 rpm, 50 rpm, 60 rpm, 70 rpm, 80 rpm, 90 rpm, 100
Rpm, 110 rpm, 120 rpm
RF (Radio Frequency): 1~10MHz
RF energy: 0~9 level corresponding to 0~50J/cm3
RF time: 0~7.5s
RF interval: 0.5s
Wave length of infrared ray: 940nm
Power: 0W, 4W, 6W, 8W, 10W, 12W, 14W, 16W, 18W, 20W.
Head of hand piece 40mmx60mm, 30mmx50mm
SwitchCentral key
Power supply mode: AC220V± 10%50Hz/AC110V± 10%60Hz (according to signs on the
Equipment)
Volume625mm× 525mm× 1070mm
Weight 47kg handpiece is included

Read 698 times Last modified on Monday, 16 February 2015 19:09