Background: Coronavirus disease 2019 (COVID-19) is an infectious disease that leads to critical respiratory problems. Obstructive sleep apnea (OSA) is the most common sleep-associated breathing disease and is represented by repetitive experiences of constraint of the respiratory tract prompting to reduced or deficient breathing during sleep. Auto-Continuous positive airway pressure (Auto-CPAP) is a modality of respiratory ventilation used as gold standart in the treatment of OSA.
Objective: This study was performed to conclude the alteration of Auto-CPAP levels in OSA patients who had COVID-19 history.
Methods: Nineteen OSA patients who had cured COVID-19 and used Auto-CPAP were included in this study. Nightly Auto-CPAP 95th percentile pressure (95thpp), median CPAP pressure and AHI before COVID-19 disease and one month after COVID therapy were recorded from electronic cards of Auto-CPAP devices.
Results: Before COVID infection, average Auto-CPAP 95thpp was 8.56 ± 0.17 cm H2O. One month after COVID-19, average Auto-CPAP 95thpp was 9.78 ± 0.21 cm H2O (P < 0.01). While Median CPAP pressure was 7.49 ± 0.16 cm H2O before COVID, it was found to be 8.15 ± 0.19 cm H2O after the disease (P < 0.01).
Conclusions: The increase in need of average Auto-CPAP 95thpp and median CPAP pressure in OSA patients who have had COVID-19 disease and use Auto-CPAP shows that this disease causes problems in both the lower and upper airways.
Keywords: Auto-CPAP; COVID-19; CPAP pressure; Obstructive sleep apnea.
Copyright © 2021 Elsevier Inc. All rights reserved.
References
1. Schwarz E.I., Schlatzer C., Stehli J. Effect of CPAP withdrawal on myocardial perfusion in OSA: a randomized controlled trial. Respirology. 2016 Aug;21(6):1126–1133. doi: 10.1111/resp.12798. – DOI – PubMed
2. May A.M., Gharibeh T., Wang L. CPAP adherence predictors in a randomized trial of moderate-to-severe OSA enriched with women and minorities. Chest. 2018 Sep;154(3):567–578. doi: 10.1016/j.chest.2018.04.010. – DOI – PMC – PubMed
3. Lebret M., Rotty M.C., Argento C. Comparison of auto- and fixed-continuous positive airway pressure on air leak in patients with obstructive sleep apnea: data from a randomized controlled trial. Can Respir J. 2019 Aug 7;2019 doi: 10.1155/2019/6310956. – DOI – PMC – PubMed
4. Diorio C., Henrickson S.E., Vella L.A. Multisystem inflammatory syndrome in children and COVID-19 are distinct presentations of SARS-CoV-2. J Clin Invest. 2020 Nov 2;130(11):5967–5975. doi: 10.1172/JCI140970. – DOI – PMC – PubMed
5. Torre C., Liu S.Y., Kushida C.A. Impact of continuous positive airway pressure in patients with obstructive sleep apnea during drug-induced sleep endoscopy. Clin Otolaryngol. 2017 Dec;42(6):1218–1223. doi: 10.1111/coa.12851. – DOI – PubMed