Introduction
• ECG300GA Is An Electrocardiograph Which Can Collect 12-Lead ECG Signal
• Simultaneously And Print Waveform By The Thermal Printing System.
• It Features In,Recording And Displaying ECG Waveform In AUTO/Manual Mode, Measuring And Diagnosing ECG Waveform Parameters Automatically
• Prompting For “Lead Off” And “Lack Of Paper”, Multi-Language Interface, Case Database Management.
Function
1. Sync Collection For 12-Lead ECG, Adopt Digital Signal Processing Technology And Get High-Quality ECG Waveform Via Power Frequency Filter, Baseline Filter And EMG Filter Of ECG Signal.
2. Display Of 1/3/6/12-Lead ECG, Print Mode, Sensitivity, Paper Speed And Filter State, Etc. On One Screen, Convenient For Contrastively Diagnosing.
3. Multiply Printing Modes And Formats, Including Manual, Auto 4×3, Auto 3×4+1, Auto 3×4, Auto 2×6+1, Auto 2×6, Etc. Waveform Length Printed Can Be Adjusted, And With Timed Print Function, Which Meets Different Requirements.
4. With The Functions Of Auto-Analysis And Auto-Diagnosis For Routine ECG Parameters, Provide Measurement Results And Auto-Diagnosis Conclusion For HR, P-R Interval, P Duration, QRS Duration, Q-T Interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5) +S(V1), Etc. Which Reduces The Doctor’s Burden.
5. Build-In Memory Stores 15 Cases, Optional SD Card Stores Up To 100 Cases, Which Is Convenient For Doctor To Review Case And Statistic.
6. Multi- Language (Chinese, English) Interface And Report.
7. Optional ECG-Sync Software, Connect With PC By USB2.0 Interface To Form An ECG Workstation, Import Real-Time Data To The Software For Analyzing And Report Printing, And Old Cases Stored In Electrocardiograph Can Be Uploaded To PC.
8. Power Supply: AC/DC And Built-In Rechargeable Lithium Battery. In Optimal DC State, Up To 4-Hour Standby Time, Continuous Print 70-Minute And 175-ECG, Which Meets The Requirements Of Visiting A Patient At Home And Body Examination.
FEATURES
• Accurate And Clear ECG Waveform
• Working State Display
• Economical To Save Recording Paper
FUNCTIONS
• Sync Collection For 12-Lead ECG Adopt Digital Signal Processing Technology To Get High-Quality ECG Waveforms Via AC Filter
• Baseline Filter And EMG Filter Of ECG Signal
• Display Of 1/2/3-Lead ECG, Print Mode, Sensitivity, Paper Speed And Filter State, Etc. On One Screen, Convenient For Contrastively Diagnosing.
PRODUCT SPECIFICATIONS
Floating And Defibrillation Safety | Input Mode |
0.05Hz ~ 150Hz(-3dB~+0.4dB) | Frequency Response |
60dB, > 100dB (Add Filter)< | CMRR |
3.2s | Time Constant |
10μA> | Patient Leakage Current |
1mV | Calibration Voltage |
2.5, 5, 10, 20, 40 Mm / MV ±5 Percent, Normal Sensitivity: 10mm / MV±2 Percent | Sensitivity |
15μVp-P> | Noise Level |
12Bit | Sampling Accuracy |
Class I, Type CF And Defibrillation-Proof Part | Safety Classification |
Thermal Printing Device | Recording Mode |
Set Auto Record Format And Mode Calculate And Analyze Automatically | Auto Recording |
Set Rhythm Recording Format And Mode | Rhythm Recording |
Set The Record Format, Switch Manually | Manual Recording |
HR, P-R Duration, P Length, QRS Duration, T Duration, Q-T Interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5) +S(V1) | Measures Of Measurement |
80mm(W)20m(L) | Paper Size |
1000Hz | Sampling Frequency |
25Hz/35Hz (-3dB) | EMG Interference Filter |
AC 50Hz/60Hz(-20dB) | Power Frequency Filter |
Auto: 25, 50mm / S, ±5 Percent Rhythm | Paper Speed |