Specifications
With the clear operating interface, analysis software is easy for you to use, which can play back and classifying dispose ECG waveform stored in recorder and achieve kinds of analysis functions, such as arrhythmia, HRV, QTD, TWA
Product Features
- ECG Holter Compact design and small size with OLED display
- With 12 leads synchro analysis QRS search can be more exactly
- Automatic Duplex Operation: 12 Channel (10-wire cable), 3 Channel (5-wire or 7-wire selectable )
- Long interval module
- Atrial flutter module
- Atrial fibrillation module etc.and multiplicative User-defined templates could almost identify every kind of pathological wave forms
- Flexible atrial fibrillation analysis so that physicians can use full segmented automatic manual analysis of atrial fibrillation make the analysis more quickly and accurately
- Powerful pacemaker analysis on the AAI VVI DDD etc. all pacemaker analysis
- Analysis of heart rate variability with short-range 5 minutes and long-range 1 hour and full analysis of heart rate variability
- Analysis can predict the risk of death in patients with myocardial infarction “Heart rate turbulence”
- Analysis is a important index on judging and preventing Arrhythmia “T Wave alternation”
- The report has more reference value with the functions of VCG VLP TVCG and QTD analysis.
- Removable TF card(volume: up to 2GB).
- Work on “AAA” size battery and workable for 60 hours.
- Separated electrodes synchronously collect the 12-lead ECG data (easy for replacement).
Product Technical Specifications
- Scale voltage: 1mV±5%
- Standard Sensitivity: 10mm/mV±5%
- Noise level: ≤30μV p-p
- CMRR: ≥60dB
- Frequency response: 10Hz as benchmark 0.5Hz~55Hz;-3dB
- Time constant: Time constant≥3.2s
- Scan speed: 25mm/s±5%
- Enduring polarization voltage: add ±300mV DC polarization voltage the sensitivity shift is no more than ± 10%
- Least measure signal: 50 μV p-p
- Interfere between channels: scan track deflexion (result from interfere between channels) ≤0.5mm
- 12-lead isochronous ECG sample
- Product safety type: Type B (Internally powered)
- Size: 80.5mm (L) *59.5mm (W) *22mm (H)
- Net Weight: 61.5g (Without battery)
Environment Condition and Applicable People
- The environment requirement of operation transport and storage for this System.
Operation Environment
- Environment Temperature: 10℃~45℃
- Relative Humidity: ≤85% no condensation.
- Atmospheric pressure : 860hPa-1060hPa
- Power Supply: DC 1.5V
1Application Environment:
- No vibration dust corrosive or combustible matter.
- No extreme temperature and humidity.
Transport and Storage Environment
Environment Temperature: -40℃~+55℃
Relative Humidity: ≤85%
Atmospheric pressure: 860hPa-1060hPa
Reviews