Semi-Automated Clinical Chemistry Analyzer With Flow-Through Cell
Possible Applications:
Biochemistry Tests On Whole Blood, Serum, Plasma, Or Urine Samples.
• Semi-Automated Photometric System
• Effective Temperature Regulation System
• Flexible Cuvette Concept, Interchangeable Flow-Through Or
Standard Cuvette
• Teach-In Capability For Reagent Applications Via Touchscreen
• Minimal Sipping Volume 250 Μl
• Double-Secured Liquid Control With Infrared Bubble Detector
• Future-Proof Operating System Can Easily Be Upgraded
TECHNICAL SPECIFICATIONS
Semi-Automatic, Single-Beam Filter Photometer | Type |
LED With Long Lifetime | Light Source |
340Nm And 380 Nm – 730 Nm | Wavelength |
Automatic Via 9-Position Filter Wheel 6Standard Interference Filters: 340 Nm, 405 Nm, 492 Nm, 546 Nm, 578 Nm And 623 Nm 3Positions For Optional Filter Of Choice |
Wavelength Selection |
0-2.5A | Photometric Range |
Micro Flow Cell: 32 Μl, 10 Mm Light Path Interchangeable With Normal Standard Cuvettes (Macro Or Semi-Micro, Disposable Or Special Optical Glass) | Cuvette System |
Internal Peltier Element, Temperature Variable, Pre-Adjusted To 25 °C, 30 °C And 37 °C
Equilibration Time For Aspirated Reaction Mixture To Reach 37 °C From Ambient Temperature: 15 Sec |
Temperature Control |
Built-In Peristaltic Pump Driven By Stepper Motor, Programmable Aspiration Volume Controlled By Infrared Light Barrier | Aspiration System |
Minimum 250 Μl, Typically 500 Μl Up To 2000 Μl
Separate Setting Of Aspirate Volume And Wash Volume |
Sipping Volume |
Touchscreen For Direct Functions And Alphanumerical Inputs | Operator Interface |
Graphic Display: White Characters Or Symbols, Blue Backlight, Dimension 240 * 128 Dots | Data Presentation |
Thermal Printer, 24 Characters Per Line | Integrated Printer |
English And French / German / Indonesian / Russian / Spanish | Languages |
General Operating Software Can Be Updated By PC
Reagent Open System With Capacity For Up To 231 Programmable Methods Import Of Data By Touchscreen Or PC Up To 50 Non-Linear Calibration Curves With Max 20 Sets Of Points Can Be Stored |
Memory |
Up To 1000 Results Can Be Saved In The Memory | Data Logging |
Serial Port For Connection To An External Printer And/Or PC
RS232 Connector For Barcode Reader For An Easy Management Of Sample Identities |
Signal Port |
Absorbance
End Point With Factor, Standard Or Multiple Standards, With Or Without Reagent Blank And/Or Sample Blank Bichromatic End Point Kinetics With Standard, Factor Or Multiple Standards, With Or Without Blank Fixed Time With Standard, Factor Or Multiple Standards, With Or Without Reagent Blank Turbidimetry Single, Double And Triple Determinations Curve Fitting For Non-Linear Standard Curves Free Hemoglobin In Combination With Optional Interference Filters |
Measurement Procedures |
Up To 50 Methods Can Be Controlled With Two Control Sera Levey Jennings Plot |
Quality Control |
Kinetic: Variable From 3 – 19 Deltas, Time Per Delta 4 – 255 Sec In 1 Sec Steps
Fixed Time: Variable From 0 – 1800 Sec In 1 Sec Steps |
Measuring Time |
Programmable From 0 – 1800 Sec In 1 Sec Steps | Delay Time |
Range: 100 VAC Up To 240 VAC At 50/60 Hz | Mains Supply |
Length 33 Cm X Width 34 Cm X Height 18 Cm | Dimensions |
5.0Kg | Weight |