Trolley-mounted anesthesia workstation AX 500-جهاز تخدير

POA
Request Price Now

Compact and integrated design; Closed and semi-closed system, suitable for patients from adult to pediatric

Warranty period: 1 year

For more information or to contact the sales specialist, click on WhatsApp
WhatsApp

Description

Trolley-mounted anesthesia workstation AX 500 Specifications

  • Compact and integrated design; Closed and semi-closed system
  • PSU plastic circuit, corrosion resistance, long service life and fully autoclavable at 134°C
  • Built-in heater and the medium copper plate eliminate the condensation of the internal water vapor effectively
  • CO2 bypass facilitates soda lime exchange during operating without any care about leakage
  • Breathing mechanics monitor: Pressure wave form, flow rate waveform, capacity waveform, CO2 wave form, 3 kinds of waveforms can be displayed on one screen simultaneously.
  • One-hand installation and dismount of soda lime canister
  • Compared with double-hand, one-hand operation keeps doctors further away from the canister waste

High Technology:

  • High quality ventilation platform suitable for patients from adult to pediatric,
  • High to low acuity, simple to complex cases all adapt. COMEN anesthesia Systems offer you the choices you need in ventilation, monitoring and technique.
  • Touch control screen design, simple user interface for fast operation
  • Speed startup, self check automatic leakage test, CO2 by-pass, provide you more Perfect workflow and distinctive clinical operation experience From appearance design, high temperature sterilization,
  • COMEN anesthesia machine provides state-of-the-art therapy solution
  • 1500ml ascending bellows, one bellows and one circuit for all patients
  • Integrated breathing circuit system, built-in flow sensors
  • Anesthetic gas and CO2 measurement optional modular design
  • Rail at each side and the top shelf feature good Patient monitoring and other equipment’s installation

Physical Characteristics:

Size773.5mm×1380mm×598mm
Weight90kg
Entire Machine Maximum Bearing Weight160kg
Screen Size8.4” TFT touch screen
Resolution 800 × 600
Handrail Length412mm
Caster wheel4 wheels 4” brakes

 Operation Environment:

Working Temp10~40°C
Humidity≤93%
Power Supply100-240V~, 50/60Hz±1Hz
Battery TypeRechargeable Lithium-ion battery
Battery Capacity4400mAh, 11.1VDC
Battery Recharging TimeMaximum 10 hours for charging
Battery backup2 hours for continuous working
TraceWaveforms: Pressure-time, Flow rate-time, Capacity-time, ET EtCO2 concentration, EEG
Optional: Pressure-volume Loops; Flow-volume Loops, Pressure- flow Loops

Top Plate:

Maximum supporting capacity20kg
Operational dimensions508mm×313mm
Dimensions with Additional Accessory508mm×313mm×380mm

Workbench:

Maximum supporting capacity20kg
Operational dimensions472mm×248mm
Dimensions with Additional Accessory472mm×248mm×380mm

Interface:

  • USB port
  • RJ45
  • Three auxiliary power output
  • AC power interface
  • Equal-potential grounding terminal
  • DB9 interface

Features:

DrawersSize: 416mm×395mm×170mm
Bearing Weight: 1Kg
Gas-bag Sway BraceLength: 320mm; Height: 240mm
Anesthesia processOpen, semi closed, closed circuit
PatientsAdult, pediatric
ModeManual, Mechanical, Standby
ComplianceCompliance Correction
ConfigurationPossibility of configuration observation
OptionalBypass; Heating; Oxygen sensor; ACGO; AGSS; BIS; CPB
MASIMO EtCO2 (side stream); MASIMO EtCO2 (mainstream); MASIMO AG (side stream) Respironics EtCO2 (mainstream)

Ventilator Specification

Ventilation Modes:

VCV/VCVolume-Controlled Ventilation with tidal volume compensation
OthersManual and automatic ventilation
OptionalPCV/VPC, SIMV-VC, PSV/ CPAP, SIMV-PC, PRVC, SIMV-PRVC, PSVPro
Ventilation principleChronometric, volumetric and barometric
VentilationElectronically controlled& pneumatically driven
Driven gasO2(air: optional)

Ventilator Setting ranges:

Monitoring parameterTidal volume, Inspiratory, expiratory flow, minute volume, frequency, pressure (Pmean, Pplat, Ppeak, PEEP), Oxygen, CO2, N2O and halogenated expiratory concentration, Pressure, oxygen, CO2, N2O and Halogen numerical values, compliance and patient resistance
Tidal volume range15 ~1500 mL
Pressure range (limit)10~100 cmH2O
Pressure range (support)3~60cmH2O
Respiratory rate4~100bpm
Inspiratory/Expiratory ratio (I: E) range4:1~1:10
Apnea I: E4:1~1:8
Apnea time10~30s
Apnea pressure3~60cmH2O
Inspiratory pauseOFF, 5~16% of inspiratory time
Inspiratory time0.2~5s
Inspiratory pressure 5~70cmH2O
PEEPOFF, 3~30cmH2O
Trigger pressure-20~-1cmH2O
Trigger window5~90%
Trigger flow0.2~15 L/ min
Flush oxygen25~75 L/ min
Inspiratory stop level5~80%
Pressure slope0~2.0s

Positive End Expiratory Pressure (PEEP):

TypeIntegrated, electronically controlled
Range0~70 cmH2O

Ventilator Monitoring Ranges:

TV (Inspiratory tidal volume)0~3000 mL
TV (Expiratory tidal volume)0~3000 mL
MV (Per-minute ventilation amount)0~100 L/min
FiO2 (Oxygen concentration)18~100%
Airway pressure-20~120cmH2O
PEEP0~70cmH2O
peak (Airway pressure)-20~120 cmH2O
Pmean (Mean pressure)-20~120cmH2O
Pplat (Platform pressure)0~120cmH2O
I: E (Inspiratory- expiratory ratio)4:1~1:12
Freq (Respiratory rate)0~120 bpm
Compl (Compliance)0~300 mL/cmH2O
Resistance0~600 cmH2O/(s/L)

EtCO2:

MASIMO EtCO2 (sidestream)0~190mmHg, 0~25% (at 760mmHg)
Accuracy: ± (0.3%+4% of reading).
MASIMO EtCO2 (mainstream)0~190mmHg, 0~25% (at 760mmHg)
Accuracy: ± (0.3%+4% of reading).
Respironics EtCO2 (mainstream)0~150mmHg, 0~19.7% (at 760mmHg)
Accuracy: 0~5.3%: ±0.3%;
5.4~9.2%: ±5% of reading;
9.3~13.2%: ±8% of reading;
13.3~19.7%: ±10% of reading

AG:

MASIMO AGSEV: 0~25%DES: 0~25%HAL/ ISO/ ENF: 0~25%
N2O: 0~100%
O2: 0~100%
CO2: 0~25% (0~190mmHg)
Accuracy:
SEV: 0~1%: ± 0.15%; 1~5%: ±0.2%; 5~8%: ±0.4%;
DES: 0~1%: ± 0.15%; 1~5%: ±0.2%; 5~10%: ±0.4%;10~15%: ± 0.6%; 15~18%: ±1%;
ISO, ENF, HAL: 0~1%: ±0.15%; 1~5vol %: ±0.2%; N2O: ± (2% + 2% of the reading)
O2: 0~25%: ±1%; 25~80%: ±2%; 80~100%: ±3%;
CO2: 0~15%: ± (0.2% + 2% of the reading); 15~25%: unspecified

Anesthesia depth:

BIS0.0~100.0
SQI0.0~100.0%
EMG0~100dB
ESR0.0~100.0%

Ventilator Performance:

Pressure range at inlet0.28~0.6 MPa
Peak gas flow100 L/min plus fresh gas
Flow valve range1~100 L/min
Flow compensation rage200 mL/min to 15 L/min
Inspiratory flowMaximum inspiratory flow shall not be smaller than 120L/min when gas supply pressure is 280KPa.
Range of flow valve3~100 L/min
PCVInspiratory pressure: ±2.5cmH2O or ±7% of set value, whichever the greater.
Limiting pressure: ±2.5cmH2O or ±7% of set value, whichever the greater.
PEEP: OFF: undefined; 3~30cmH2O: ±2.0cmH2O, or ±8% of set value, whichever is the greater.
Supporting pressure: ±2.5cmH2O or ±7% of set value, whichever the greater.
Apnea pressure: ±2.5cmH2O or ±7% of set value, whichever the greater.
Trigger pressure: ±2.0cmH2O.
Freq±1 bpm or ±5% of set value, whichever is the greater.
I: E2: 1~1: 4: ±10% of reading value;
Other ranges: ±25% of reading value.
Apnea I: E2: 1~1: 4: ±10% of set value;
Other ranges: ±25% of set value.
Tip: Ti20%~60%: ±15% of set value;
Other ranges: undefined.
Inspiratory time±0.2s
Inspiratory pause20%~60%: ±15% of set value;
Other ranges: undefined.
Trigger window±10%
Trigger flow rate±1 L/ min
Inspiratory stop level±10%
O2/ N2O/ Air flow control10~100% of the full scale: ±10% of the reading value. Other ranges: undefined.
Total flow controlAir balance gas: ≤±3%
N2O balance gas: ≤±3%
Backup flow controlPure Oxygen flow rate is 0~10 L/min: ≤±3%; Others: undefined.
Auxiliary flow control10~100% of the full scale: ±10% of the reading value. Other ranges: undefined.

Vaporizer:

BrandPenlon available
LockingVaporizer with interlocking system (Optional: Two vaporizers)
Automatic recognitionAnesthesia machine able to automatic recognize halogenated gases

Power (No isolation transformer)

External AC power supply:

Input voltage100~240 V~/ 100~120V~
Input current3.5~8.5 A/8.5 A
Input frequency50/60 Hz

Auxiliary output supply

Output voltage100~240 V~/ 100~120V~

 

Reviews (0)

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.