Mammography Navigator DR Care(Digital)-جهاز تصوير الثدي الشعاعي ديجيتال

POA
Request Price Now

The SINOMDT Navigator DR Care equipment is a model with 24 x 30 cm amorphous silicon detector with digital system

Warranty period: 1 year

For more information or to contact the sales specialist, click on WhatsApp
WhatsApp

Description

Specifications

  • Safe and adaptable
  • The SINOMDT Navigator DR Care equipment is a model with 24 x 30 cm amorphous silicon detector with digital system.
  • Its perfect adaptation allows it to be used indoors and in mobile units depending on its use.
  • Our team has international certifications which reaffirm trust in the team and the brand.

Flat Panel

  • Large flat panel detector made of amorphous silicon, in addition to facilitating workflow, it provides high image resolution.

Plus

GUI Easy to use graphical interface
Efficiency Data collection, image reconstruction, visualization and measurement, typesetting, printing and storage.
DICOM 3.0 DICOM 3.0 protocol can achieve seamless link with HIS, RIS and PACS systems.

Excellent ergonomics

  • High-end IAE RX tube
  • Swivel arm from -135 ° to 180 °
  • Station with independent design
  • 6 operating panels

Configurations & Specifications of Navigator DR Mammography

1.Mammography System

Rating power 5000VA
Integrated System Generator Integrated within the main device
High voltage generator output ≥100 kHz, 20 kV to 40 kV increment
step 1 kV
High performance X-ray tube Standard: Molybdenum Anode, Focal Spot Size: 0.1 mm (Small)/ 0.3 mm (Large)

Optional: Tungsten Anode, Focal Spot Size: 0.1 mm (Small)/ 0.3 mm (Large)

Support iso center rotation function
C-arm Rotation range +180°~ -135°
Height range of breast support surface 735mm-1315mm
C-arm power-driven electrically Dual side digital display
Compression plate flexible and multi-level smart Compression
Spatial Resolution >6 Lp/mm
Detector type Amorphous Silicon Detector
Effective Imaging Area 24*30cm
Acquisition Station compatible with DICOM 3.0
Focal distance 650mm
Added filter Mo / Rh
Added filter Switch Manual/Automatic
X-ray Field adjustment Manual
Magnification factor 1.5
Exposure mode Manual / AEC
Supply 220V~, ±10%
Frequency 50/60Hz±1Hz
Max. power 5000 VA
N.W 240 Kg
Compact design, minimum device height < 1.1 m
Packing Size 121 X 94 X 145 CM

2.High-Voltage Generator

Frequency ≥100KHz
Tube voltage Range 20 kV ~ 40 kV in 1 kV step
Max Output 4 kW
Max tube voltage 40kV
Max tube current 140mA
Max current time product ≥630mAs
Ripple <4%

3.X-Ray Tube

Standard Imported X-ray tube for Mammography
Anode Type Molybdenum
Focal Spot Size 0.1 mm (Small)/ 0.3 mm (Large)
Permanent filtration 0.5mmBe
Max anode speed 10000rpm/min
Max tube voltage 40kV
Max tube current 35mA(small)/140mA(Large)
Anode heating capacity 300 kHu
Optional Imported X-ray tube for Mammography;
Anode Type Tungsten
Focal Spot Size 0.1 mm (Small)/ 0.3 mm (Large)
Permanent filtration 0.5mmBe
Max anode speed 10000rpm/min
Max tube voltage 49kV
Max tube current 35mA(small)/140mA(Large)
Anode heating capacity 300 kHu

4.Beam Limiting Device

  • Electric switch between Molybdenum or Tungsten added filter Adjustable X-ray field manually.
  • Light field indicator is on automatically as compression plate moves down.
  • Light field indicator is off with delay as compression plate stops moving.
  •   Off delay of light field indicator can be set via software.

5.C-arm Assembly

  • C-arm up-down and rotation movement controlled via C-arm control panel
  • Rotation angle of OBL position can be set via software
  • Device can be installed in the movable physical vehicle as max height of device is less than 110cm
  • Local display panel on the both side of the stand can indicate rotation angle of C-arm
  • For safer operation, emergency stop button is locating on the top of C-arm
  • Duplex foot switch(2 pcs) provided
C-arm stops automatically at common mammographic position CC, OBL and LAT
Support table up-down range 735mm(L)~1315mm(H)
Rotation type of C-arm iso center rotation around the examined part
Rotation range of C-arm -135o~180o
Distance between focal spot and image reception area 650mm
Magnification factor 1.5

6.Compression Device

Up-down movement power-driven electrically
Compression control continuous activation by foot
Compression mode flexible and multi-level compression, automatic and manual decompression
Compression plate travel range 5~268mm
Compression force 0~200N
Compression thickness 5~268mm
Size of compression plate 24X30cm
Reviews (0)

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.