Specifications
- Safe and adaptable
- The SINOMDT Navigator DR Care equipment is a model with 24 x 30 cm amorphous silicon detector with digital system.
- Its perfect adaptation allows it to be used indoors and in mobile units depending on its use.
- Our team has international certifications which reaffirm trust in the team and the brand.
Flat Panel
- Large flat panel detector made of amorphous silicon, in addition to facilitating workflow, it provides high image resolution.
Plus
GUI | Easy to use graphical interface |
Efficiency | Data collection, image reconstruction, visualization and measurement, typesetting, printing and storage. |
DICOM 3.0 | DICOM 3.0 protocol can achieve seamless link with HIS, RIS and PACS systems. |
Excellent ergonomics
- High-end IAE RX tube
- Swivel arm from -135 ° to 180 °
- Station with independent design
- 6 operating panels
Configurations & Specifications of Navigator DR Mammography
1.Mammography System
Rating power | 5000VA |
Integrated System | Generator Integrated within the main device |
High voltage generator output | ≥100 kHz, 20 kV to 40 kV increment |
step | 1 kV |
High performance X-ray tube | Standard: Molybdenum Anode, Focal Spot Size: 0.1 mm (Small)/ 0.3 mm (Large)
Optional: Tungsten Anode, Focal Spot Size: 0.1 mm (Small)/ 0.3 mm (Large) |
Support | iso center rotation function |
C-arm Rotation range | +180°~ -135° |
Height range of breast support surface | 735mm-1315mm |
C-arm power-driven electrically | Dual side digital display |
Compression plate | flexible and multi-level smart Compression |
Spatial Resolution | >6 Lp/mm |
Detector type | Amorphous Silicon Detector |
Effective Imaging Area | 24*30cm |
Acquisition Station compatible | with DICOM 3.0 |
Focal distance | 650mm |
Added filter | Mo / Rh |
Added filter Switch | Manual/Automatic |
X-ray Field adjustment | Manual |
Magnification factor | 1.5 |
Exposure mode | Manual / AEC |
Supply | 220V~, ±10% |
Frequency | 50/60Hz±1Hz |
Max. power | 5000 VA |
N.W | 240 Kg |
Compact design, minimum device height | < 1.1 m |
Packing Size | 121 X 94 X 145 CM |
2.High-Voltage Generator
Frequency | ≥100KHz |
Tube voltage Range | 20 kV ~ 40 kV in 1 kV step |
Max Output | 4 kW |
Max tube voltage | 40kV |
Max tube current | 140mA |
Max current time product | ≥630mAs |
Ripple | <4% |
3.X-Ray Tube
Standard | Imported X-ray tube for Mammography |
Anode Type | Molybdenum |
Focal Spot Size | 0.1 mm (Small)/ 0.3 mm (Large) |
Permanent filtration | 0.5mmBe |
Max anode speed | 10000rpm/min |
Max tube voltage | 40kV |
Max tube current | 35mA(small)/140mA(Large) |
Anode heating capacity | 300 kHu |
Optional | Imported X-ray tube for Mammography; |
Anode Type | Tungsten |
Focal Spot Size | 0.1 mm (Small)/ 0.3 mm (Large) |
Permanent filtration | 0.5mmBe |
Max anode speed | 10000rpm/min |
Max tube voltage | 49kV |
Max tube current | 35mA(small)/140mA(Large) |
Anode heating capacity | 300 kHu |
4.Beam Limiting Device
- Electric switch between Molybdenum or Tungsten added filter Adjustable X-ray field manually.
- Light field indicator is on automatically as compression plate moves down.
- Light field indicator is off with delay as compression plate stops moving.
- Off delay of light field indicator can be set via software.
5.C-arm Assembly
- C-arm up-down and rotation movement controlled via C-arm control panel
- Rotation angle of OBL position can be set via software
- Device can be installed in the movable physical vehicle as max height of device is less than 110cm
- Local display panel on the both side of the stand can indicate rotation angle of C-arm
- For safer operation, emergency stop button is locating on the top of C-arm
- Duplex foot switch(2 pcs) provided
C-arm stops automatically at common mammographic position | CC, OBL and LAT |
Support table up-down range | 735mm(L)~1315mm(H) |
Rotation type of C-arm | iso center rotation around the examined part |
Rotation range of C-arm | -135o~180o |
Distance between focal spot and image reception area | 650mm |
Magnification factor | 1.5 |
6.Compression Device
Up-down movement | power-driven electrically |
Compression control | continuous activation by foot |
Compression mode | flexible and multi-level compression, automatic and manual decompression |
Compression plate travel range | 5~268mm |
Compression force | 0~200N |
Compression thickness | 5~268mm |
Size of compression plate | 24X30cm |