Mindray BeneFusion VP3 Volumetric Infusion Pump with a Drug Library and ±5% Accuracy
A Mindray volumetric infusion pump with ≤ ±5% accuracy, a flow rate from 0.1 to 2000 ml/h in 0.01 ml/h steps, and a drug library of up to 200 drugs. It detects air bubbles from 20 µL, has 14 occlusion alarm levels and works with universal IV sets. The physician sets the fluid and the dose.
1-year warranty
On Mindray devices, from the date of purchase.
Lifetime service
With genuine spare parts after the warranty too.
Accredited maintenance centre
By the General Authority for Industrial Control.
Ali Ben Ali
In the medical equipment trade since 1987, with 4 branches.
This device may suit you if...
The final choice is made with the physician or the biomedical engineering team. These are the uses the device is made for.
Weight-based drugs
Body-weight mode and dose units such as ug/kg/min.
A hospital that wants to use its own IV sets
Works with universal IV sets.
Patient transfer and emergency
Battery back-up, suitable for ambulances (EN 1789).
A volumetric pump draws from the bag or bottle through an IV set, so it suits larger volumes than a syringe pump. ±5% accuracy means the volume delivered stays within 5% of what was set. Bubble detection from 20 µL means the pump alarms on a very small air bubble, and the drug library lets the nurse pick the drug by name.
BeneFusion VP3 features
≤ ±5% accuracy
Flow 0.1 to 2000 ml/h, minimum increment 0.01 ml/h.
Drug library of up to 200 drugs
Plus a 2000-record log and volume totals in 4 ways.
7 infusion modes
Rate (drip mode), Body Weight, Time, Sequential, Loading Dose, Micro-infusion and Ramp.
Air bubble detection
6 levels from 20 to 800 µL, plus accumulated-air monitoring in the line.
14 occlusion levels
From 75 to 1050 mmHg, with anti-bolus protection after an occlusion.
Battery and ambulance use
At least 4 hours at 25 ml/h, suitable for ambulances (EN 1789), IP34.
Technical specifications
Infusion
- Infusion accuracy
- ≤ ±5%
- Flow rate range
- 0.1–2000 ml/h
- Rate increment
- Minimum increment 0.01 ml/h
- Infusion modes
- 7 modes: Rate (drip mode), Body Weight, Time, Sequential, Loading Dose, Micro-infusion and Ramp
- Drug library
- Up to 200 drugs, can be switched on or off
- IV administration sets
- Universal IV sets
- Volume to be infused (VTBI)
- 0.1–9999 ml in 0.1 ml steps; preset time 00:00:01–99:59:59
- KVO rate
- 0.1–30 ml/h, default 0.5 ml/h
- Bolus rate
- 0.1–2000 ml/h, automatic or manual
- Purge rate
- 0.1–2000 ml/h
Safety
- Air bubble detection
- 6 levels: 20, 50, 100, 250, 500 and 800 µL; accumulated air 0.1–4 ml/h
- Occlusion pressure levels
- 14 levels from 75 to 1050 mmHg; pressure shown in mmHg, kPa, bar or psi
- Anti-bolus after occlusion
- Yes
- Keypad lock
- Auto-lock after 1–5 minutes, on/off
Display
- Screen size
- 3 inch
- Display
- Monochrome LCD, 240 × 128 pixels, 8 brightness levels; shows the drug name and remaining time
Data & connectivity
- History log
- Up to 2000 records
- Interfaces
- RS232, nurse call connector, DC adapter
Alarms
- Alarms
- Audible and visual alarms in 3 levels (high, medium, low), volume 1–8
Power
- Battery
- Battery runs at least 4 hours at 25 ml/h
- Battery charging time
- 6 hours at most
- Power input
- 100–240 V, 50/60 Hz
- Water ingress protection
- IP34
Physical
- Operating conditions
- 5–40 °C, 15–95% humidity
- Weight
- 1.8 kg≤
- Dimensions
- 150 × 100 × 200 mm
Warranty & after-sales
- Ali Ben Ali warranty
- 1 year
Identity
- Ambulance use
- Suitable for ambulances (EN 1789)
Compare with other Volumetric infusion pump devices
| BeneFusion VP3This page | BeneFusion VP1Go to product | |
|---|---|---|
| Infusion accuracy | ≤ ±5% | ≤ ±5% |
| Flow rate range | 0.1–2000 ml/h | 0.1–1500 ml/h |
| Rate increment | Minimum increment 0.01 ml/h | 0.1 ml/h |
| Infusion modes | 7 modes: Rate (drip mode), Body Weight, Time, Sequential, Loading Dose, Micro-infusion and Ramp | Rate mode |
| Drug library | Up to 200 drugs, can be switched on or off | – |
| IV administration sets | Universal IV sets | Automatic recognition of IV sets |
| Air bubble detection | 6 levels: 20, 50, 100, 250, 500 and 800 µL; accumulated air 0.1–4 ml/h | 5 levels: 50, 100, 250, 500 and 800 µl |
| KVO rate | 0.1–30 ml/h, default 0.5 ml/h | 0.5 ml/h, fixed |
| Bolus rate | 0.1–2000 ml/h, automatic or manual | 0.1–1500 ml/h |
| Occlusion pressure levels | 14 levels from 75 to 1050 mmHg; pressure shown in mmHg, kPa, bar or psi | 3 levels: 150, 525 and 900 mmHg |
| Screen size | 3 inch | 2.5 inch |
| History log | Up to 2000 records | – |
| Battery | Battery runs at least 4 hours at 25 ml/h | Lithium battery, at least 4 hours at 25 ml/h |
| Water ingress protection | IP34 | IP34 |
| Weight | 1.8 kg (≤) | 1.5 kg (≤) |
| Dimensions | 150 × 100 × 200 mm | 150 × 90 × 200 mm |
| Ali Ben Ali warranty | 1 year | 1 year |
A dot next to a value means it differs from the device on this page.
Frequently asked questions
About the BeneFusion VP3
What is the difference between the VP3 and the VP1?
Both are ≤ ±5% accurate. The VP3 adds a drug library of up to 200 drugs, 7 modes instead of rate mode only, flow up to 2000 ml/h in 0.01 ml/h steps (the VP1 goes to 1500 ml/h), 14 occlusion levels instead of 3, bubble detection from 20 µL instead of 50 µl, and a 3.0-inch screen instead of 2.5.
Who loads the drug library and sets the dose?
The department prepares the drug library (the pharmacist or the person in charge of the devices), the physician prescribes the dose, and a trained nurse loads the IV set and selects the drug and mode. Auto-lock prevents accidental changes.
Does it work with any IV set?
Yes, it works with universal IV sets, and the screen shows the IV set brand. Order any spare part from customer service on 01212333328.
Does it run on mains or battery?
Both. It runs on 100–240 V mains; if the power goes, the battery gives at least 4 hours at 25 ml/h, and charges in 6 hours at most.
What happens if there is air in the line?
The pump stops the infusion and alarms when it finds a bubble larger than the level set (20 to 800 µL), or when accumulated air passes the set limit. Clear the air from the line and carry on.
About buying medical devices from Ali Ben Ali
Is the device genuine, and how can I be sure?
The device is made by Mindray and comes with the Ali Ben Ali warranty; we have been in the medical equipment trade since 1987. You can also see it in person at any of our branches before you buy.
About usHow long is the warranty, and who provides it?
1 year from Ali Ben Ali from the date of purchase, on Mindray devices. We honour it directly, not through a third party; for any coverage question call the hotline 01212333328.
Maintenance centresIf the device breaks after the warranty, who repairs it?
Our maintenance centre at 31 El Rashidy St – Kasr El Aini, accredited by the General Authority for Industrial Control. Service and genuine spare parts stay available for the device's whole life.
Maintenance centresCan I return or exchange the device?
Yes, within 14 days of delivery, if it is unused, complete with its accessories and in its original packaging. If it arrives defective or different from your order, we replace it or refund it in full. Masks, tubing and any items that contact the patient cannot be returned once opened, for hygiene reasons. Return shipping is on us for a defect or a wrong item; otherwise the customer pays it, unless a free-shipping offer applies.
Exchange and returns policyDo you deliver and install? Should I buy online or at a branch?
We deliver and install in 27 governorates within Egypt. Shipping fees are set after you order and agreed with you by phone or WhatsApp before dispatch. Order on the website or on WhatsApp, or visit our branches: Rashidy and Bostan in Cairo, Alexandria and Mansoura.
Branches and contactCustomer reviews
Only logged in customers who have purchased this product may leave a review.
Specifications last updated: 2026-09-25









Reviews
Clear filtersThere are no reviews yet.