Mindray BeneFusion VP1 Volumetric Infusion Pump with ±5% Accuracy and Air Bubble Detection
A Mindray volumetric infusion pump with ≤ ±5% accuracy and a flow rate from 0.1 to 1500 ml/h, which recognises the IV set by itself. It has 5-level air bubble detection and 3 occlusion alarm levels. The physician sets the fluid and the rate.
1-year warranty
On Mindray devices, from the date of purchase.
Lifetime service
With genuine spare parts after the warranty too.
Accredited maintenance centre
By the General Authority for Industrial Control.
Ali Ben Ali
In the medical equipment trade since 1987, with 4 branches.
This device may suit you if...
The final choice is made with the physician or the biomedical engineering team. These are the uses the device is made for.
Wards that need a controlled IV volume
Instead of counting drops by hand.
Patient transfer and emergency
Light, long battery life, suitable for ambulances (EN 1789).
Nursing staff who want a simple pump
One rate mode, and the IV set is easy to load.
Volumetric pump versus syringe pump, in one line: a syringe pump pushes from a small syringe (up to 60 ml), while a volumetric pump draws from the bag or bottle through an IV set, so it suits larger volumes. ±5% accuracy means the volume delivered stays within 5% of what was set. Bubble detection in µl is the smallest air bubble the pump alarms on.
BeneFusion VP1 features
≤ ±5% accuracy
Flow 0.1 to 1500 ml/h, in 0.1 ml/h steps.
Air bubble detection
5 levels: 50, 100, 250, 500 and 800 µl.
Occlusion alarm
3 levels: 150, 525 and 900 mmHg, with anti-bolus protection after an occlusion.
Clear alarms
Air in line, door opened, empty bottle, drop error, VTBI done.
Long battery life
At least 4 hours at 25 ml/h; charges in 6 hours at most.
Compact and ambulance ready
1.5 kg at most, suitable for ambulances (EN 1789), IP34, connects to nurse call and RS232.
Technical specifications
Infusion
- Infusion accuracy
- ≤ ±5%
- Flow rate range
- 0.1–1500 ml/h
- Rate increment
- 0.1 ml/h
- Infusion modes
- Rate mode
- IV administration sets
- Automatic recognition of IV sets
- Volume to be infused (VTBI)
- 0.1–9999 ml
- KVO rate
- 0.5 ml/h, fixed
- Bolus rate
- 0.1–1500 ml/h
- Purge rate
- 600 ml/h, fixed
Safety
- Air bubble detection
- 5 levels: 50, 100, 250, 500 and 800 µl
- Occlusion pressure levels
- 3 levels: 150, 525 and 900 mmHg
- Anti-bolus after occlusion
- Yes
- Keypad lock
- Auto-lock after 1–5 minutes, off by default
- Electrical safety class
- Class I, type CF
Display
- Screen size
- 2.5 inch
- Display
- Monochrome LCD, 132 × 32 pixels
Data & connectivity
- Interfaces
- RS232, nurse call, DC input, dock support
Alarms
- Alarms
- Occlusion, air in line, door opened, empty bottle, drop error, VTBI done or near done, battery low or empty, AC power disconnection, system error
Power
- Battery
- Lithium battery, at least 4 hours at 25 ml/h
- Battery charging time
- 6 hours at most
- Power input
- 100–240 V, 50/60 Hz
- Water ingress protection
- IP34
Physical
- Operating conditions
- 0–40 °C, 15–95% humidity
- Weight
- 1.5 kg≤
- Dimensions
- 150 × 90 × 200 mm
Warranty & after-sales
- Ali Ben Ali warranty
- 1 year
Identity
- Mounting
- Vertical pole clamp
- Ambulance use
- Suitable for ambulances (EN 1789)
Compare with other Volumetric infusion pump devices
| BeneFusion VP1This page | BeneFusion VP3Go to product | |
|---|---|---|
| Infusion accuracy | ≤ ±5% | ≤ ±5% |
| Flow rate range | 0.1–1500 ml/h | 0.1–2000 ml/h |
| Rate increment | 0.1 ml/h | Minimum increment 0.01 ml/h |
| Infusion modes | Rate mode | 7 modes: Rate (drip mode), Body Weight, Time, Sequential, Loading Dose, Micro-infusion and Ramp |
| Drug library | – | Up to 200 drugs, can be switched on or off |
| IV administration sets | Automatic recognition of IV sets | Universal IV sets |
| Air bubble detection | 5 levels: 50, 100, 250, 500 and 800 µl | 6 levels: 20, 50, 100, 250, 500 and 800 µL; accumulated air 0.1–4 ml/h |
| KVO rate | 0.5 ml/h, fixed | 0.1–30 ml/h, default 0.5 ml/h |
| Bolus rate | 0.1–1500 ml/h | 0.1–2000 ml/h, automatic or manual |
| Occlusion pressure levels | 3 levels: 150, 525 and 900 mmHg | 14 levels from 75 to 1050 mmHg; pressure shown in mmHg, kPa, bar or psi |
| Screen size | 2.5 inch | 3 inch |
| History log | – | Up to 2000 records |
| Battery | Lithium battery, at least 4 hours at 25 ml/h | Battery runs at least 4 hours at 25 ml/h |
| Water ingress protection | IP34 | IP34 |
| Weight | 1.5 kg (≤) | 1.8 kg (≤) |
| Dimensions | 150 × 90 × 200 mm | 150 × 100 × 200 mm |
| Ali Ben Ali warranty | 1 year | 1 year |
A dot next to a value means it differs from the device on this page.
Frequently asked questions
About the BeneFusion VP1
What is the difference between the VP1 and the VP3?
Both are ≤ ±5% accurate. The VP3 adds a drug library of up to 200 drugs, 7 modes instead of rate mode only, flow up to 2000 ml/h in 0.01 ml/h steps, 14 occlusion levels instead of 3, bubble detection from 20 µL instead of 50 µl, and works with universal IV sets.
Who sets the rate and volume?
The physician prescribes the fluid and rate; a trained nurse loads the IV set and enters the figures. Auto-lock prevents accidental changes.
Does it work with any IV set?
The pump recognises the IV set loaded in it by itself. Before buying, confirm with our sales team which IV set you will use; order any spare part from customer service on 01212333328.
Does it run on mains or battery?
Both. It runs on 100–240 V mains; if the power goes, the battery gives at least 4 hours at 25 ml/h, and the pump alarms when mains is disconnected or the battery runs low.
What happens if there is air in the line?
The pump stops the infusion and alarms when it finds a bubble larger than the level set (50 to 800 µl). Clear the air from the line and carry on.
About buying medical devices from Ali Ben Ali
Is the device genuine, and how can I be sure?
The device is made by Mindray and comes with the Ali Ben Ali warranty; we have been in the medical equipment trade since 1987. You can also see it in person at any of our branches before you buy.
About usHow long is the warranty, and who provides it?
1 year from Ali Ben Ali from the date of purchase, on Mindray devices. We honour it directly, not through a third party; for any coverage question call the hotline 01212333328.
Maintenance centresIf the device breaks after the warranty, who repairs it?
Our maintenance centre at 31 El Rashidy St – Kasr El Aini, accredited by the General Authority for Industrial Control. Service and genuine spare parts stay available for the device's whole life.
Maintenance centresCan I return or exchange the device?
Yes, within 14 days of delivery, if it is unused, complete with its accessories and in its original packaging. If it arrives defective or different from your order, we replace it or refund it in full. Masks, tubing and any items that contact the patient cannot be returned once opened, for hygiene reasons. Return shipping is on us for a defect or a wrong item; otherwise the customer pays it, unless a free-shipping offer applies.
Exchange and returns policyDo you deliver and install? Should I buy online or at a branch?
We deliver and install in 27 governorates within Egypt. Shipping fees are set after you order and agreed with you by phone or WhatsApp before dispatch. Order on the website or on WhatsApp, or visit our branches: Rashidy and Bostan in Cairo, Alexandria and Mansoura.
Branches and contactCustomer reviews
Only logged in customers who have purchased this product may leave a review.
Specifications last updated: 2026-09-25









Reviews
Clear filtersThere are no reviews yet.