SPIROMETER TYPE:PRO-سبيروميتر-جهاز لقياس التنفس و وظائف الرئة

POA
Request Price Now

The portable pulmonary function measurement instrument can be used to measure vital capacity (VC), forced vital capacity (FVC), Maximum Ventilator Volume (MVV)

Warranty period: 1 year
For more information or to contact the sales specialist, click on WhatsApp
WhatsApp

Description

Specifications

  • The portable pulmonary function measurement instrument can be used to measure vital capacity (VC), forced vital capacity (FVC), Maximum Ventilator Volume (MVV). Measurement algorithm refers to the ITS, ERS standards of the American Thoracic Society (ATS)
  • Measuring principle
    When be normally breathing, the gas passed through the flow sensor. On both sides of the screen of the sensor will produce different pressure. The pressure is detected by the sensor, which is converted to electrical signals. After the signal amplification, AD converter sampling, the pressure is converted to digital signal into the computer system.
  • Through digital signal processing and analyzing technology, computer system reproduces the breathing waves that are displayed on the LCD together with analyzed results. In the end the built-in printer prints out the analysis results. Single use filter
  • Single use mouth set
  • Nose clip

Features

  • The portable pulmonary function measurement instrument can be used to measure:
  • Vital capacity (VC)
  • Forced vital capacity (FVC)
  • Maximum Ventilator Volume (MVV).
  • Measurement algorithm refers to the ITS ERS standards of the American Thoracic Society (ATS)

Measurement of breathing time:

  • VC time 50 seconds
  • FVC measuring time 25 seconds
  • MVV time 12 seconds in favor of the coordination between patients and the device
  • Adopting pressure-flow sensor sensitive precise easy to launder clean and durable
  • All parameters can be displayed on large screen (320 x 240)
  • Built-in memory can store maximum 300 cases of patient measurement results
  • The instrument can calibrate automatically all English operation more convenient to operate 110mm thermal printer built-in can print out a clear clinical report predicted value measured value
  • Compact and flexible
  • SpioSoft PC Software for data transfer (Options)

Measurement methods:

Flow velocity detectionScreen type pneumotachograph flow sensor
Capacity detectionflow integration

Patient Data:

  Patient   information
input
Patient IDID No.: XXXXXXID No.: XXXXXX
GenderGender:Gender:
AgeAge:Age:Years old
HeightHeight:Height:cm
WeightWeight:Weight:kg
RaceRace:Race:
TemperatureTemperature:Temperature:
HumidityHumidity:Humidity:%
AtmosphereAtmosphere:Atmosphere:mmHg

Measuring range:

Capacity range0L ~ 9L
Flow velocity range0 ~ 14L / s

Measurement accuracy

Capacity0L ~ 1.6L (± 50ml)
6L ~ 9L (± 3%)
Flow rate5% or 0.2L / s
Respiratory rate4 / 20 ~ / min (± 1 / min)
20 / 60 / min (error: ± 5%)

Measuring time limit and degree

VC50s per time, measuring 3 times
FVC25s per time, measuring 3 times
MVV12 seconds per time, measuring 3 times
PARAMETER DESCRIPTIONDISPLAYPRINTUNIT
VC TestVital capacity,Maximum inspiration volume or Maximum exhalation volumeVCVCL
Tidal volumeTVTVL
Expiratory reserved volumeERVERVL
Inspiratory reserved volumeIRVIRVL
Inspiratory capacityICICL
FVC TestForced vital capacityFVCFVCL
Forced expiratory volume at 0.5secFEV0.5FEV0.5L
Forced expiratory volume at 1secFEV1.0FEV1.0L
Forced expiratory volume at 3secFEV3.0FEV3.0L
Forced expiratory volume1sec / Forced vital capacityFEV1.0/GFEV1.0/G%
Forced expiratory volume1sec / vital capacityFEV1.0%TFEV1.0%T%
Forced expiratory volume at 3sec / Forced vital capacityFEV3.0%GFEV3.0%G%
Forced expiratory volume at 3sec / vital capacityFEV3.0%TFEV3.0%T%
Extrapolated volumeVextVextL
Expiratory timeEX TimeEX Times
Maximal mid-expiratory flowMMFMMFL/s
Peak expiratory flowPEFPEFL/s
Mid(forced)-expiratory flow at 75%MEF75MEF75L/s
Mid(forced)-expiratory flow at 50%MEF50MEF50L/s
Mid(forced)-expiratory flow at 25%MEF25MEF25L/s
Forced inspiratory vital capacityFIVCFIVCL
Forced inspiratory volume at 0.5secFIV0.5FIV0.5L
Forced inspiratory volume at 1.0secFIV1.0FIV1.0L
Ratio of FIV1.0divided by FIVCFIV1.0/FVCFIV1.0/FVC%
Ratio of FIV1.0divided by FVCFIV1.0/FIVCFIV1.0/FIVC%
Peak inspiratory flowPIFPIFL/s
Inspiratory flow at 50%MIF50%MIF50%L/s
MVV TestMaximum voluntary ventilationMVVMVVL/min
Respiration rateRRRR/min
Tidal volumeTVTVL
Display (LCD(320 * 240 dot-matrix
printer110mm thermal printer
Data10 integral records

Other Note

PowerA.C. 100~220V 50/60Hz
The type of securityI Class B type

Transport and storage note

Ambient temperature range-20°C ~ 55°C
Relative humidity range≤ 93%
Atmosphere pressure range500hPa ~ 1060hPa

Working note

Surrounding temperature range10°C ~ +40°C
Relative humidity range30% to 75%
Atmosphere pressure range700hPa ~ 1060hPa

Options

  • SpioSoft PC Software for data transfer (Options)

 

Reviews (0)

Reviews

There are no reviews yet.