LED Surtron 50D Monopolar 50 W Electrosurgical Unit for Minor Surgery
A monopolar electrosurgical (diathermy) unit from Italy's LED SpA, made for minor surgery. It cuts at up to 50 W and offers pure cut, two cut-coagulation levels and coagulation, with a digital display. It weighs 2.5 kg. The surgeon sets the mode and power for each procedure.
2-year warranty
On Surtron devices, from the date of purchase.
Lifetime service
Service and genuine spare parts, after the warranty too.
Accredited maintenance centre
By the General Authority for Industrial Control.
Direct LED agent
In the medical equipment trade since 1987, with 4 branches.
This device may suit you if...
The final choice is made with the surgeon or the biomedical engineering team. These are the uses the device is made for.
A dental, dermatology or day-surgery practice
Suited to dental, dermatology, ambulatory surgery, first aid and vascular surgery.
Your work is monopolar only
This unit is monopolar. For bipolar, the Surtron 80 and above have it.
You need a small unit
190 × 85 × 239 mm and 2.5 kg.
Monopolar vs bipolar in one line: in monopolar the current leaves the pen and returns through a neutral plate on the patient's body; in bipolar it passes only between the two tips of the forceps.
Surtron 50D features
Pure cut up to 50 W
At 400 Ω, with an on-board microcontroller controlling the output.
Two cut-coagulation levels
CUT/COAG 1 at 45 W and CUT/COAG 2 at 40 W.
Coagulation up to 40 W
COAG mode at 400 Ω.
Digital display and self check
Output power monitoring and a self check.
Genuine accessories available
Genuine LED handles, cables and foot switches are available from us.
Runs on 115 or 230 V
Selectable voltage, 50–60 Hz.
Technical specifications
Output & modes
- Output type
- Monopolar
- Maximum cutting power
- 50 Wat 400 Ω
- Maximum monopolar coagulation power
- 40 WCOAG, at 400 Ω
- Cutting and coagulation modes
- Pure CUT, cut-coagulation CUT/COAG 1 and CUT/COAG 2, and COAG
- Output per mode
- CUT 50 W / 400 Ω · CUT/COAG1 45 W / 400 Ω · CUT/COAG2 40 W / 400 Ω · COAG 40 W / 400 Ω
- Working frequency
- 600 kHz
Safety
- Safety controls
- Output power monitoring, self check
- Electrical safety and standards
- Class I, type CF · EN 60601-1, EN 60601-1-2, EN 60601-2-2 · MDD 93/42/EC class IIb
Power
- Power input
- 115/230 V AC selectable, 50–60 Hz
- Electrical input power
- 280 VA
Physical
- Weight
- 2.5 kg
- Dimensions
- 190 × 85 × 239 mmW × H × D
Warranty & after-sales
- Ali Ben Ali warranty
- 2 years
Identity
- Specialties
- Dental, dermatology, ambulatory surgery, first aid, vascular surgery, veterinary
Compare with other Electrosurgical unit devices
| SURTRON 50DThis page | SURTRON 80Go to product | SURTRON 120Go to product | |
|---|---|---|---|
| Output type | Monopolar | Monopolar and bipolar (bipolar with a special adapter) | Monopolar and bipolar (bipolar with a special adapter) |
| Maximum cutting power | 50 W (at 400 Ω) | 80 W (at 250 Ω) | 120 W (at 250 Ω) |
| Maximum monopolar coagulation power | 40 W (COAG, at 400 Ω) | 50 W (FORCED COAG, at 150 Ω) | 80 W (FORCED COAG, at 150 Ω) |
| Bipolar coagulation power | – | 30 W (at 100 Ω) | 40 W (at 100 Ω) |
| Cutting and coagulation modes | Pure CUT, cut-coagulation CUT/COAG 1 and CUT/COAG 2, and COAG | Pure CUT, cut-coagulation BLEND, superficial FORCED COAG, deep SOFT COAG without necrosis, BIPOLAR coagulation | Pure CUT, cut-coagulation BLEND, superficial FORCED COAG, deep SOFT COAG without necrosis, BIPOLAR coagulation |
| Working frequency | 600 kHz | 600 kHz | 600 kHz |
| Minimally invasive surgery | – | Yes | Yes |
| Activation from handpiece or pedal | – | Yes | Yes |
| Settings memory | – | Remembers the last settings used; working conditions can be planned | Remembers the last settings used; working conditions can be planned |
| Neutral-plate contact monitoring | – | Yes | Yes |
| Electrical input power | 280 VA | 230 VA | 300 VA |
| Weight | 2.5 kg | 5 kg | 5 kg |
| Dimensions | 190 × 85 × 239 mm (W × H × D) | 254 × 104 × 288 mm (W × H × D) | 254 × 104 × 288 mm (W × H × D) |
| Ali Ben Ali warranty | 2 years | 2 years | 2 years |
A dot next to a value means it differs from the device on this page.
Frequently asked questions
About the SURTRON 50D
What is the difference between the Surtron 50D and the Surtron 80?
The 50D is monopolar only, cuts at up to 50 W and weighs 2.5 kg. The Surtron 80 is monopolar and bipolar (bipolar with a special adapter), cuts at up to 80 W, adds BLEND, superficial and deep coagulation, monitors the neutral plate, and weighs 5 kg.
Who sets the mode and power?
The surgeon sets the mode and power for each procedure and tissue. The unit shows the settings on a digital display.
Does it monitor the neutral plate?
Patient/plate circuit monitoring is on the 80D only, not the 50D. The 50D monitors its output power and runs a self check. Surtron units from the 80 up monitor the neutral plate.
Are accessories and spare parts available?
Yes, genuine LED accessories such as handles, cables and foot switches are available from us.
What power supply does it need?
115 or 230 V, selectable, 50–60 Hz; electrical input power 280 VA.
About buying medical devices from Ali Ben Ali
Is the device genuine, and how can I be sure?
We are a direct agent of the manufacturer; the device comes straight from the factory with the Ali Ben Ali warranty. You can also see it in person at any of our branches before you buy.
About usIs the device registered with the Egyptian Drug Authority?
Yes, this device is registered with the Egyptian Drug Authority.
How long is the warranty, and who provides it?
2 years from Ali Ben Ali from the date of purchase, on Surtron devices. We honour it directly, not through a third party; for any coverage question call the hotline 01212333328.
Maintenance centresIf the device breaks after the warranty, who repairs it?
Our maintenance centre at 31 El Rashidy St – Kasr El Aini, accredited by the General Authority for Industrial Control. Service and genuine spare parts stay available for the device's whole life.
Maintenance centresCan I return or exchange the device?
Yes, within 14 days of delivery, if it is unused, complete with its accessories and in its original packaging. If it arrives defective or different from your order, we replace it or refund it in full. Masks, tubing and any items that contact the patient cannot be returned once opened, for hygiene reasons. Return shipping is on us for a defect or a wrong item; otherwise the customer pays it, unless a free-shipping offer applies.
Exchange and returns policyDo you deliver and install? Should I buy online or at a branch?
We deliver and install in 27 governorates within Egypt. Shipping fees are set after you order and agreed with you by phone or WhatsApp before dispatch. Order on the website or on WhatsApp, or visit our branches: Rashidy and Bostan in Cairo, Alexandria and Mansoura.
Branches and contactCustomer reviews
Only logged in customers who have purchased this product may leave a review.
Specifications last updated: 2026-09-13






































Reviews
Clear filtersThere are no reviews yet.