LED Surtron Touch HP Touchscreen 400 W Electrosurgical Unit
A new-generation electrosurgical unit from Italy's LED SpA with a 9-inch touchscreen. It cuts at up to 400 W, has two monopolar and two bipolar outputs that can run together, an integrated argon unit, cutting in saline (TUR) and vessel sealing up to 7 mm. Power adapts to tissue impedance and neutral-plate contact is monitored continuously. The surgeon sets the mode and power.
2-year warranty
On Surtron devices, from the date of purchase.
Lifetime service
Service and genuine spare parts, after the warranty too.
Accredited maintenance centre
By the General Authority for Industrial Control.
Direct LED agent
In the medical equipment trade since 1987, with 4 branches.
This device may suit you if...
The final choice is made with the surgeon or the biomedical engineering team. These are the uses the device is made for.
A theatre with two surgeons
Two surgeons can work at once, and monopolar and bipolar can run together.
Urology and endoscopy
Underwater cutting and coagulation, bipolar cutting in saline (TUR), and use in minimally invasive surgery.
Argon without a second unit
An integrated argon unit, flow 0.2 to 10 L/min.
Monopolar vs bipolar in one line: in monopolar the current leaves the pen and returns through a neutral plate on the patient's body; in bipolar it passes only between the two tips of the forceps.
See the device on video
The manufacturer's device video · SURTRON TOUCH HPSurtron Touch HP features
9-inch touchscreen
A capacitive touchscreen; the LeOS system lets you change power and save your work settings at a touch, on a white or black screen.
Cutting up to 400 W
PURE at 300 Ω, ENHANCED for high impedance, BLEND for wet conditions, DUO with two handpieces at once, and TUR.
Integrated argon
SPRAY ARGON up to 120 W, flow 0.2 to 10 L/min, maximum inlet pressure 3 bar.
Full bipolar
Vessel sealing up to 7 mm, cutting and coagulation in saline (TUR), MICRO, and automatic start/stop.
A light for each output
Each side socket has its own coloured light showing whether it is cutting or coagulating; it stays white while waiting.
Lighter than the previous generation
13.5 kg, 25% lighter, with HF leakage control and mains fluctuation compensation.
Technical specifications
Output & modes
- Output type
- Two monopolar and two bipolar outputs, usable simultaneously
- Maximum cutting power
- 400 Wat 300 Ω
- Maximum monopolar coagulation power
- 150 WFORCED and SOFT COAG, at 200 Ω
- Bipolar coagulation power
- 150 Wat 50 Ω
- Cutting and coagulation modes
- Monopolar cut: PURE, ENHANCED for high impedance, BLEND for wet conditions, DUO with two handpieces at once, TUR. Monopolar coag: FORCED, SOFT, FULGURATION, DUO, SPRAY, SPRAY ARGON. Bipolar: cut PURE, TUR, MICRO; coag BIPOLAR, SEALING, TUR, MICRO
- Output per mode
- Monopolar: PURE 400 W / 300 Ω · ENHANCED 250 W / 300 Ω · BLEND 250 W / 200 Ω · cut DUO 200 W / 300 Ω · TUR 300 W / 300 Ω · FORCED 150 W / 200 Ω · SOFT 150 W / 200 Ω · FULGURATION 100 W / 300 Ω · coag DUO 100 W / 300 Ω · SPRAY 120 W / 500 Ω · SPRAY ARGON 120 W / 500 Ω. Bipolar: cut PURE 150 W / 50 Ω · cut-coag TUR 300 W / 300 Ω · cut-coag MICRO 50 W / 50 Ω · coag TUR 250 W / 25 Ω · SEALING 250 W / 25 Ω · BIPOLAR 150 W / 50 Ω · coag MICRO 50 W / 50 Ω
- Working frequency
- 360 kHz
- Two surgeons at once
- Yes
- Vessel sealing up to
- 7 mm
- Argon
- Integrated argon unit: flow 0.2–10 L/min, maximum inlet pressure 3.0 bar
- Cutting in saline (TUR)
- Yes
- Power adapts to tissue impedance
- Yes
- Bipolar auto start / stop
- Yes
- Minimally invasive surgery
- Yes
- Activation from handpiece or pedal
- Yes
- Settings memory
- Customise and save your work settings (LeOS)
Safety
- Neutral-plate contact monitoring
- Yes
- Safety controls
- Patient/plate circuit monitoring, output power monitoring, self check, HF leakage current control, mains fluctuation compensation, sound intensity adjustment
- Electrical safety and standards
- Class I, type CF · EN 60601-1, EN 60601-1-2, EN 60601-2-2 · MDR 2017/745/UE class IIb
Display
- Screen size
- 9 inch
- Touchscreen
- Yes
Power
- Power input
- 100–240 V AC, 50/60 Hz
- Electrical input power
- 1000 VA
Physical
- Weight
- 13.5 kg
- Dimensions
- 470 × 220 × 460 mmW × H × D
Warranty & after-sales
- Ali Ben Ali warranty
- 2 years
Compare with other Electrosurgical unit devices
| SURTRON TOUCH HPThis page | SURTRON 400HPGo to product | SURTRON 200Go to product | |
|---|---|---|---|
| Output type | Two monopolar and two bipolar outputs, usable simultaneously | Monopolar with two outputs, and bipolar | Monopolar and bipolar, independent outputs |
| Maximum cutting power | 400 W (at 300 Ω) | 400 W (at 300 Ω) | 200 W (at 250 Ω) |
| Maximum monopolar coagulation power | 150 W (FORCED and SOFT COAG, at 200 Ω) | 120 W (SPEEDY COAG at 500 Ω, DEEP COAG at 200 Ω) | 150 W (FORCED COAG, at 150 Ω) |
| Bipolar coagulation power | 150 W (at 50 Ω) | 120 W (at 50 Ω) | 80 W (at 50 Ω) |
| Cutting and coagulation modes | Monopolar cut: PURE, ENHANCED for high impedance, BLEND for wet conditions, DUO with two handpieces at once, TUR. Monopolar coag: FORCED, SOFT, FULGURATION, DUO, SPRAY, SPRAY ARGON. Bipolar: cut PURE, TUR, MICRO; coag BIPOLAR, SEALING, TUR, MICRO | Monopolar: pure CUT, cut-coag CUT 80% / 60% / 40%, ENHANCED, BLEND, SPEEDY coag, DEEP coag, SPRAY, SPRAY ARGON. Bipolar: CUT, cut-coag CUT 80% / 60% / 40%, BLEND, COAG, VESSEL SEALING | Pure CUT, ENHANCED incision with reduced eschar, cut-coagulation BLEND, superficial FORCED COAG, deep SOFT COAG without necrosis, BIPOLAR COAG |
| Working frequency | 360 kHz | 425 kHz monopolar / 525 kHz bipolar | 600 kHz |
| Two surgeons at once | Yes | Yes | – |
| Vessel sealing up to | 7 mm | 7 mm | – |
| Argon | Integrated argon unit: flow 0.2–10 L/min, maximum inlet pressure 3.0 bar | Output driver for an external argon plasma unit and a smoke evacuator | – |
| Cutting in saline (TUR) | Yes | – | – |
| Power adapts to tissue impedance | Yes | Yes | – |
| Bipolar auto start / stop | Yes | Yes | Yes |
| Minimally invasive surgery | Yes | Yes | Yes |
| Activation from handpiece or pedal | Yes | Yes | Yes |
| Settings memory | Customise and save your work settings (LeOS) | Ten personal procedures, configurable and immediately recallable | Stores working conditions; working conditions can be planned |
| Neutral-plate contact monitoring | Yes | Yes | Yes |
| Screen size | 9 inch | – | – |
| Touchscreen | Yes | – | – |
| Electrical input power | 1000 VA | 1000 VA | 350 VA |
| Weight | 13.5 kg | 17.5 kg | 6 kg |
| Dimensions | 470 × 220 × 460 mm (W × H × D) | 470 × 150 × 400 mm (W × H × D) | 370 × 144 × 319 mm (W × H × D) |
| Ali Ben Ali warranty | 2 years | 2 years | 2 years |
A dot next to a value means it differs from the device on this page.
Frequently asked questions
About the SURTRON TOUCH HP
What is the difference between the Surtron Touch HP and the Surtron 400HP?
Both cut at up to 400 W, seal vessels up to 7 mm and let two surgeons work at once. The Touch HP adds a 9-inch touchscreen, an integrated argon unit, cutting in saline (TUR) and two bipolar outputs, and weighs 13.5 kg. The 400HP drives an external argon unit and weighs 17.5 kg.
Who sets the mode and power?
The surgeon sets the mode and power for each procedure and tissue. Settings are changed and saved on the touchscreen.
What does the argon need?
The unit is built into the device. Argon flow is 0.2 to 10 L/min, with a maximum gas inlet pressure of 3 bar.
Are accessories and spare parts available?
Yes, genuine LED accessories such as handles, cables and foot switches are available from us.
What power supply does it need?
100–240 V, 50/60 Hz; electrical input power 1000 VA.
About buying medical devices from Ali Ben Ali
Is the device genuine, and how can I be sure?
We are a direct agent of the manufacturer; the device comes straight from the factory with the Ali Ben Ali warranty. You can also see it in person at any of our branches before you buy.
About usIs the device registered with the Egyptian Drug Authority?
Yes, this device is registered with the Egyptian Drug Authority.
How long is the warranty, and who provides it?
2 years from Ali Ben Ali from the date of purchase, on Surtron devices. We honour it directly, not through a third party; for any coverage question call the hotline 01212333328.
Maintenance centresIf the device breaks after the warranty, who repairs it?
Our maintenance centre at 31 El Rashidy St – Kasr El Aini, accredited by the General Authority for Industrial Control. Service and genuine spare parts stay available for the device's whole life.
Maintenance centresCan I return or exchange the device?
Yes, within 14 days of delivery, if it is unused, complete with its accessories and in its original packaging. If it arrives defective or different from your order, we replace it or refund it in full. Masks, tubing and any items that contact the patient cannot be returned once opened, for hygiene reasons. Return shipping is on us for a defect or a wrong item; otherwise the customer pays it, unless a free-shipping offer applies.
Exchange and returns policyDo you deliver and install? Should I buy online or at a branch?
We deliver and install in 27 governorates within Egypt. Shipping fees are set after you order and agreed with you by phone or WhatsApp before dispatch. Order on the website or on WhatsApp, or visit our branches: Rashidy and Bostan in Cairo, Alexandria and Mansoura.
Branches and contactCustomer reviews
Only logged in customers who have purchased this product may leave a review.
Specifications last updated: 2026-09-13





































Reviews
Clear filtersThere are no reviews yet.